We take this opportunity in stating that BELL COOLING TOWERS are unique by being the only Forced
Draught Fibreglass Cooling Towers with a complete range. It has the following distinct advantages over
any other Induced Draught Tower:-
ECONOMY IN POWER CONSUMPTION:-
Being
forced draught, the fan handles cold and dry air with much less
specific volume and hence air flow quantity is lesser, for a given
duty, than Induced Draught. Also BELL uses specially designed PVC
fills which has lesser static resistance than any other type of
fills. And finally the velocity pressure which is wasted into the
atmosphere in Induced Draught towers, is utilized effectively in
Forced Draught towers contributing in saving of power.
ECONOMY IN WATER CONSUMPTION:-
As the
exit air velocity is less in a Forced Draught tower, the carry over
loss is reduced. Coupled with this, very high efficiency drift
eliminators reduce the total drift loss to max. 0.05% compared with
0.2 - 0.3% for other type of towers. This also eliminates the drift
nuisance as well as algae formation around the towers.
ECONOMY IN SPACE CONSUMPTION:-
As the
air entry to the cooling tower is from one side and discharge is
from the top of the cooling tower, the clearance required for forced
draught towers is only from one side, whereas for Induced Draught
towers, clearance from all the sides of the cooling towers needed,
effectively requiring more space.
EASY MAINTENANCE:- Over and above the
preceding points, the forced draught tower has moving parts near the
foundation increasing stability and life. The fan handles dry, air,
therefore the problem of corrosion is reduced considerably and
moisture - condensation, motor burnouts are also eliminated.
Maintenance is easier as the fan is near the ground and easily
accessible. The top of the tower is open, hence internals are also
easily accessible.
TECHNICALLY SUPERIOR TOWER INTERNALS:
Coupled with this, BELL has an unpressurised gravity flow
distribution system requiring minimum of maintenance, eliminating
the possibilities of breakdowns due to clogging of nozzles or
sprinkler holes.
All PVC Fills are double folded with an automatic drainage system,
producing a favourable pressure drop and a good protection against
erosion. They are glued by automatic process and manufactured with
German Technology. The fills can easily withstand temperature upto
65 C. High Efficiency Drift Eliminators manufactured with German
design ensure a maximum drift loss of 0.05% under standard design
conditions. The sub-distribution pipes are made of rigid PVC with a
testing - pressure of 6 Kg/cm2.
LONG LASTING EXTERNAL PANELS:
The cooling tower panels and main troughs are of corrosion resistant
fibreglass with a longer service life and available in various
colour choices. BELL uses superior quality isothelic resin and FRP
matting, making the components stronger for withstanding wind
pressures.
ESPECIALLY DESIGNED FANS & STANDARD MOTORS:
The Axial Flow Fans are statically balanced and manufactured in
strick conformation to renowned American Designs. All motors are of
standard make TEFC, with IP 55 protection and co-guaranteed by the
original Manufacturers such as SIEMENS, NGEF, ABB, KIRLOSKAR and
others. All the fans are direct driven, eliminating any gear box
problems as experienced in other cooling towers.
TWIN FANS & MOTORS:
Moreover, in the higher range of towers of capacities of 175 TR and
above, BELL supplies them with twin / multiple fans & motors
enabling you to further save on power, if the plant operates on
partial load. In case of hospitals, hotels etc. where there is a 24
hours operation, any changes of breakdown is eliminated because the
plant can still be run on part load. Periodic servicing can be
carried out without any shutdowns.
All the above features make BELL COOLING TOWERS give HIGHER THERMO
DYNAMIC EFFICIENCY benefiting the user in several ways and saving in
running costs.
Search
| Home | Enquiry
|